Home / RAID 5 Data Recovery

RAID 5 Data Recovery Swansea

There's no need for a RAID 5 to be lost when one of its disks drops out, or when the rebuild fails mid-rebuild or if the controller dies; the member drives will usually still contain all the data you require. All drives will be imaged to allow us to re-assemble the RAID in software without ever writing to an original drive.

▲

Every RAID case starts with a free diagnostic. Pricing is from £500 + VAT, priced per disk, and prior to starting recovery work we will provide you with a single written quote. On logical rebuilds, in most cases you only pay if we recover your data.

// what brings raid 5 arrays down

How a RAID 5 lets go

The first disk failure can leave you still able to recover in RAID 5. It's the second failure that causes the problem. These are the types of failure we see from Swansea servers and NAS systems.

The rebuild claims a second disk

Swapping for a replacement drives many hours of heavy reads on existing old and weary survivor disks. If one of them gives up while being used during the rebuild process, a degraded array becomes a dead one, which is far and away the most common type of RAID 5 emergency.

Dead controller, HBA or backplane

This problem can come from a dead HBA (host bus adapter), controller or backplane. Your disks can be perfectly healthy, but as long as there is some type of failed hardware surrounding them the volume can't be accessed until both the configuration and parity metadata are retrieved from each member, even though the data itself is intact.

A stale member forced back in

If a disk drops from the array and then gets put back in later, the data on that disk will have been frozen at the point in the past when it was last active. The other disks however are able to continue working as usual. When the old disk is added back into the array (re-added), the data that had been written since this disk left the array is going to be intermixed with what existed prior to the disk leaving. As a result of adding an older disk to the array, parity values across every stripe will become corrupted.

Bad sectors on several members

When you encounter a read error on one disk, parity can handle this, but if there are matching errors in the same place on two disks, parity cannot fix this. Therefore we image around the weak sectors on every member disk before attempting any reconstruction.

Re-created or re-initialised sets

Using the 'repair' options on the dashboard, recreating the array or reinitialising it can overwrite the metadata describing where your actual data resides.

An expansion that never finished

Expanding to add space or changing from one RAID level to another takes a long time and is fragile. If interrupted part-way through this process, the array will be left stranded between two layouts and nothing on it will mount.

// how raid 5 recovery works

Members imaged first — the array never runs again

None of our recovery steps touch your original disks. First, each member is imaged to a stable image using hardware imaging systems; before that, if there was mechanical failure in one of the drives it would have been repaired on the bench. After that we work out from the images which order the disks go in, what the stripe size is, how they rotate, and which direction the parity runs. Then we create an assembly of the virtual array and pull your files off, and the originals remain untouched throughout as the final fallback.

Resist the urge to rebuild

Dropping in a new disk to let the controller "rebuild" appears to be doing something useful, however, on an array that has already used up its safety margin it will put you at your greatest risk; the remaining healthy disks will be running at maximum capacity just when they are at their weakest point, and if another disk fails while rebuilding then what was once recoverable becomes a hard case. If a rebuild has already stalled or thrown errors, shut the machine down and leave it that way.

Server and NAS arrays across South Wales

The majority of RAID 5 systems we receive here are used as primary data stores for small businesses, mainly Dell PowerEdge, HP ProLiant and Lenovo servers, bespoke builds and Synology, QNAP and Netgear NAS systems from businesses throughout Swansea, Llanelli, Neath, Port Talbot and the M4 corridor. Following quotation, the disk drives are then posted into our Bristol location, tracked and insured, with each drive labelled according to its position (bay). Alternatively the disk drives can be dropped off there Monday to Friday, 9am to 5:30pm, with no appointment needed. Business-critical arrays can be moved to the front of the bench. For details see our RAID recovery service and NAS recovery service pages, and see our data recovery costs page for information regarding prices.

// related services

More we can help with

// raid 5 questions answered

Common questions

Nearly all of the time, and it's the RAID 5 scenario we deal with most. All members are imaged exactly as found and then reconstructed into an array in software using the images created for each member; therefore a stalled rebuild is no barrier to this. The critical thing to avoid is making another effort at the rebuild: shut down the system, get a quote and send the set of disks.
You can send the individual disks. Remove each drive member and label each with its original bay location, get a quote and send the complete set of all disks (and any disk which may have previously been removed due to failure). Leave your chassis behind, and call us first if you're in any doubt.
Depending on the number of disks within your RAID 5 array, recovery starts from £500 + VAT, since each disk must be independently imaged prior to rebuilding. The initial free diagnostic provides you with a single fixed written figure for the total price. How this pricing structure works is explained in detail on our data recovery cost page.
Yes, where the disks are sound and only need a logical rebuild: in most cases you only pay if we recover your data. Invasive bench work on individual disks will be required if they have suffered damage due to either electronic failure, mechanical failure, physical damage, water ingress or fire damage. Half of the quote for these disks must be paid for up front for parts and labour, and this amount will also be agreed and written down prior to commencing any work.
Once the disks arrive, your complimentary diagnostic is finished within 2 working days. On approval of your quotation, an uncomplicated rebuild is commonly completed within about a week. Depending on the capacity, number of array members and whether there's a physical repair needed, that time could be extended. If the system is business-critical, it can move to the front of our bench.

Array down? The data usually isn’t.

Just shut it down (if it's running), obtain a quote for the rebuild, send us the member disks and we'll rebuild it all virtually, with a complimentary diagnostic and a fixed written quotation to price out the rebuild before we begin.

// getting your device to us

Post your device to us — it's simple

First get a quote over the telephone or use our free on-line diagnostic. The majority of customers then have their media sent to us via post, this is tracked and insured.

Do you want to send a drive from your computer, laptop, MacBook, iMac, CCTV / DVR or server? Please do not send the complete unit of computer or device with a hard disk drive (HDD) or solid state drive (SSD) inside. Please remove it and only send the drive itself. For a server, please remove all disks and label them by their bay. We will also not perform removal of internal drives from devices in order to access data. Also, we will not extract data from devices where storage is soldered onto the motherboard (such as T2 and Apple Silicon Macs and some thin laptops). Additionally, we do not recover data from phones and tablets, only drives that can be removed and sent to us. If you're not sure which kind you have, ring us first.

  • Encase the unit in bubble wrap or a padded envelope. A single external drive will come as one complete package including its outer case, cable and power supply; for anything other than that there is no requirement to send cables or power supplies.
  • Print and include the booking-in & shipping form (PDF) with your name, phone number and a short explanation of what occurred.
  • Please post your item to us using a method such as Royal Mail Special Delivery (or a similar secure tracked and insured delivery method that you would normally use), so it's covered the whole way.
  • Alternatively, if you wish to hand-deliver your item, after receiving your quote please drop it into our reception area at the address shown during opening hours (Monday to Friday, 9am to 5:30pm), with no appointment needed.
// send your device to your nearest location

Bristol Data Recovery

Castlemead
Lower Castle Street
Bristol, BS1 3AG

↓ Print the booking-in & shipping form (PDF)

Clearly mark the parcel with the name Bristol Data Recovery, and when your media has been diagnosed we will call you immediately.

If unsure about what to post, please call us first on 0800 689 0668 (the free phone number), or complete a free online diagnostic.